⚡ The Power Bench
Home / Blog / Best CO Shutoff Generators
Buying guide

Best Generators With Carbon Monoxide Shutoff

Carbon monoxide from portable generators kills people every year. Generators with CO sensing and automatic shutoff reduce that risk. Here is how to choose one.

Updated September 17, 20266 min readThe Power Bench editorial

We earn a commission when you buy through links on this page, at no cost to you. We do not accept free products for coverage, and we never invent test results, prices, or ratings.

Why CO shutoff matters

Portable generators produce a lot of carbon monoxide. The U.S. Consumer Product Safety Commission estimates that portable generators are associated with an average of nearly 80 CO poisoning deaths each year. Many of those deaths happen when generators are run in garages, basements, or too close to the house during outages.

Generators with carbon monoxide shutoff have a built-in CO sensor. When CO around the generator reaches a dangerous level, the generator shuts itself off. It is not a substitute for proper placement and indoor CO alarms, but it is an important additional layer of protection.

The two certifications to look for

Two voluntary safety standards cover CO safety on portable generators:

CPSC staff analysis found that generators meeting UL 2201 would avert nearly all of the deaths in the incidents studied, and those meeting PGMA G300 would avert about 87 percent. The difference comes largely from UL 2201's reduced-emission requirement. For the full breakdown, read our explainer on UL 2201 vs PGMA G300.

Manufacturers usually mark compliance on the packaging and in product descriptions. Look for the standard name, not just a vague "CO safety" claim.

Worth knowing

Marketing names vary by brand, such as "CO Protect," "CO-Minder," "CO Guard," or "CO Sense." The brand feature name is not the standard. Check the specifications for PGMA G300 or UL 2201 compliance.

What to look for beyond CO shutoff

Our picks by category

Inverter generator with CO shutoff (small)

$$

Best for Camping, RV, and light home backup

Quiet and fuel-efficient with clean power and a CO shutoff sensor. Check the listing for PGMA G300 or UL 2201 compliance.

Dual-fuel inverter generator with CO shutoff (mid-size)

$$$

Best for Home backup with clean power

Enough capacity for a furnace, refrigerator, and essentials, with CO shutoff and dual-fuel flexibility. Look for a transfer switch outlet.

Open-frame dual-fuel generator with CO shutoff

$$

Best for More watts per dollar for home backup

Conventional generators with CO shutoff are widely available. Check the certification and the THD rating if you plan to power electronics.

Large home backup generator with CO shutoff

$$$

Best for Homes with well pumps or large loads

Higher capacity and 240V output, with CO shutoff. Pair with a transfer switch or interlock.

Battery CO alarm for the home

$

Best for Everyone running a generator

A CO shutoff generator protects the area around the generator. You still need CO alarms inside the house on every level.

How CO shutoff works

A CO sensor near the generator measures carbon monoxide concentration. When levels exceed a threshold, either an instantaneous high reading or an elevated average over time, the system shuts down the engine. The generator typically indicates the reason with a light. After a shutdown, move the generator to a safer location before restarting. Never restart it in the same place.

Safety

CO shutoff is a backup, not permission to run a generator indoors. Run generators outdoors only, far from the house, with the exhaust pointed away from doors, windows, and vents. CPSC recommends at least 20 feet from the home. Never run one in a garage, even with the door open.

Existing generators without CO shutoff

If you own an older generator without CO shutoff, you do not need to discard it, but be extra careful:

Regulatory status

CPSC began rulemaking on portable generator CO hazards in 2016 and published a supplemental proposal in 2023. As of our most recent check, a mandatory federal rule has been proposed but not finalized. The voluntary standards remain the main benchmark. Check CPSC for the current status.

Placement is still the most important step

Even with CO shutoff, where you put the generator matters most. Keep it outdoors, away from the house, and protected from rain and snow with a cover rated for use while running, not by moving it into a garage or under a porch.

Buying checklist

Before you buy, confirm these in the product listing or manual:

  1. Standard compliance: "Complies with ANSI/PGMA G300" or "certified to UL 2201" stated clearly.
  2. Running and starting watts: enough for your essential loads with headroom.
  3. Outlet types: a locking 30-amp or 50-amp outlet if you plan to use a transfer switch or interlock.
  4. Fuel type: gasoline only, or dual fuel for propane flexibility.
  5. Noise level: inverter models are much quieter, which matters for neighbors during long outages.
  6. Parts and service: a brand with accessible service centers and replacement parts.

Common questions about nuisance shutoffs

Some owners worry that CO sensors will shut the generator down unexpectedly. A shutdown means the sensor detected elevated CO around the generator, which usually means it is too close to a wall, in a partially enclosed space, or in a spot where exhaust collects, such as a corner or under an overhang. Treat any CO shutdown as a warning to move the generator farther out into open air.

Wind can also blow exhaust back toward the generator in some locations. If shutdowns happen repeatedly, try a more open location with the exhaust pointed downwind and away from the house.

Why emissions reduction matters

A shutoff system reacts after CO has built up. Reducing emissions at the source means CO builds up more slowly in the first place, which gives people more time to notice and escape if a generator is misused. That is the main reason CPSC staff found UL 2201 more protective in their simulations. For more detail on the standards, read our UL 2201 vs PGMA G300 explainer.

Pairing a generator with indoor alarms

Think of CO safety in layers: correct placement outdoors, a generator with CO shutoff, and CO alarms inside the home. Each layer covers weaknesses in the others. Interconnected alarms, where one sounding triggers all of them, add another layer of protection in larger homes.

CO shutoff on inverter vs conventional generators

CO shutoff is available on both inverter and conventional open-frame generators, across many sizes. Inverter models tend to be quieter and more fuel-efficient at partial load, which suits long outages with light loads. Conventional models deliver more watts per dollar for larger loads. Choose the type based on your power needs, then filter for CO shutoff certification.

Renting a generator

If you rent a generator during a storm, ask whether it has CO shutoff and which standard it meets. Rental fleets may include older units without it. Whatever you rent, follow the same rules: outdoors only, far from the house, with CO alarms inside.

Placement quick reference

Store the manual with the generator

Keep the owner's manual, including the section explaining the CO shutoff indicator lights, in a zip bag with the generator. During a stormy night is not the time to search online for what a flashing light means. Knowing whether a shutdown came from CO, low oil, or overload tells you exactly what to fix before restarting.

Frequently asked questions

What does CO shutoff on a generator do?

It uses a carbon monoxide sensor to shut the generator off automatically when CO levels around it become dangerous.

Is UL 2201 better than PGMA G300?

CPSC staff analysis estimated UL 2201 would avert nearly all deaths studied versus about 87 percent for PGMA G300, largely because UL 2201 also requires reduced emissions.

Can I run a CO shutoff generator in the garage?

No. CO shutoff is a backup safety feature. Generators must run outdoors, away from the house.

Do I still need CO alarms if my generator has CO shutoff?

Yes. Install battery-operated or battery-backup CO alarms on every level of your home and outside sleeping areas.

Is there a federal rule requiring CO shutoff?

CPSC has proposed a mandatory rule, but as of our latest check it has not been finalized. Voluntary standards are the current benchmark.