How to Keep Your Heat On During a Winter Power Outage

Most modern heating systems stop working when the power goes out, even if they burn gas or oil. Here is what each type needs, how to size a generator for it, and how to connect safely.

Updated September 17, 202610 min readThe Power Bench editorial

We earn a commission when you buy through links on this page, at no cost to you. We do not accept free products for coverage, and we never invent test results, prices, or ratings.

Why your heat stops when the power does

It surprises many people: a natural gas or propane furnace goes cold during a power outage even though the gas line is still full. That is because the furnace depends on electricity for nearly everything except the flame itself. The blower motor that pushes warm air through the ducts, the draft inducer that vents exhaust, the igniter, the control board, the gas valve, and the thermostat all need power.

Boilers are similar. The burner may run on gas or oil, but circulator pumps move the hot water, and a control board runs the whole system. Heat pumps are fully electric and among the largest loads in a house. Even pellet stoves, which burn fuel you stack in the garage, need electricity to feed pellets and run fans.

So the question in a winter outage is not just "Do I have fuel?" It is "Can I power the equipment that uses the fuel?" The good news is that gas furnaces, boilers, and pellet stoves draw relatively modest amounts of electricity, and a properly connected portable generator or large power station can run them. Heat pumps are a different story, and this guide explains why.

Step 1: Identify your heating system

Walk to your mechanical room and look. Most homes have one of these:

Each has very different power needs. Read the nameplate or data sticker on the equipment for voltage, amperage, and motor ratings. That label is your most reliable source of information.

Step 2: Understand the power each system needs

Gas and oil furnaces

The largest electrical load in a gas furnace is the blower motor. Blower motors vary widely in size and type. Older furnaces often use permanent split capacitor (PSC) motors, while many newer ones use electronically commutated (ECM) motors, which are more efficient. Running loads for a furnace blower commonly fall in the range of a few hundred watts up to around a thousand watts or so, and motors draw more briefly at startup. Add the draft inducer, igniter, and controls, and most gas furnaces can be run by a modest generator.

To estimate, find the blower motor amperage on the nameplate, multiply by 120 volts for running watts, and leave headroom for startup.

Oil furnaces have the same blower plus an oil burner motor and ignition transformer, which add some load.

Boilers

Hot water boilers are usually the lightest load of all. Circulator pumps are small, and the control board and gas valve use little power. A boiler with one or two circulators may run on a small inverter generator or a mid-size power station. Steam boilers may also have a condensate or feed pump.

Heat pumps

Heat pumps are the challenge. The outdoor compressor is a large motor, and the startup surge can be several times its running draw. Most whole-house heat pumps run on 240 volts. On top of that, many systems have electric resistance backup heat strips, which can draw enormous amounts of power, far more than most portable generators can supply.

Running a heat pump on a generator is possible, but it usually requires:

We cover this in detail in our comparison of heat pump vs gas furnace on a generator.

Pellet stoves

Pellet stoves run an auger motor, a combustion blower, and a convection fan, plus an igniter during startup. Running loads are typically modest, with a spike during ignition. Many owners run them on small inverter generators or power stations. See our guide to the best generators for pellet stoves.

Space heaters

Plug-in electric space heaters typically draw up to about 1,500 watts on high, which is a significant load for a small generator and quickly drains a power station. They can work as a supplement, but they are an inefficient way to heat a house from a generator compared with running a fuel-burning furnace or boiler.

Heating systemTypical electrical loadGenerator class that usually worksNotes
Gas/propane furnaceBlower plus controls, modestMid-size inverter or largerNeeds clean power and proper connection
Oil furnaceBlower plus burner motorMid-size inverter or largerCheck nameplate
Hot water boilerCirculators plus controls, lightSmall inverter or power stationOften the easiest to back up
Heat pumpLarge compressor, 240V, big surgeLarge 240V generator, soft start helpsBackup heat strips are usually too much
Pellet stoveAuger, fans, igniter spikeSmall inverter or power stationVery manageable
Electric space heaterUp to about 1,500W eachMid-size generatorInefficient supplement only

Step 3: Clean power matters for modern heating equipment

Modern furnaces and boilers use electronic control boards. Some are sensitive to the quality of the electricity they receive. Conventional open-frame generators can produce power with more voltage fluctuation and harmonic distortion than utility power. Inverter generators produce cleaner, more stable power.

Many HVAC technicians and furnace manufacturers recommend clean power for electronic controls. If you are buying a generator specifically to run a furnace or boiler, an inverter generator, or a conventional generator with low rated total harmonic distortion, is the safer choice. Our list of the best generators for furnaces focuses on clean-power options.

The grounding and flame sensing issue

Some furnaces rely on a flame sensor that uses a tiny electrical current through the flame to confirm ignition. This process depends on a proper neutral-to-ground reference. Some portable generators have a floating neutral, meaning the neutral is not bonded to the frame. When such a generator is connected in certain ways, the furnace may fail to confirm the flame and lock out after a few ignition attempts.

When a generator is connected through a properly installed transfer switch or interlock, the home's neutral-ground bond is usually preserved, which avoids the issue. If you are experiencing lockouts on generator power, have a licensed electrician or HVAC technician evaluate the connection. Do not improvise bonding plugs or modifications without professional advice.

Step 4: Connect safely

A furnace is hardwired, not plugged in. That means you cannot run an extension cord to it unless an electrician has installed a proper connection. The safe options are:

  1. Manual transfer switch or interlock kit on your main panel. A licensed electrician installs an inlet box outside and a transfer switch or interlock at the panel. You plug the generator into the inlet and select which circuits to power, including the furnace. This is the most common and flexible solution. See our guide on how to connect a generator to your house.
  2. Dedicated furnace transfer switch. A single-circuit switch installed near the furnace, with a plug or inlet for the generator. It is simpler and cheaper for people who only want to back up the furnace.
  3. Whole-home standby generator with automatic transfer switch. The most convenient, but a separate category from portable generators.
Safety

Never backfeed your home by plugging a generator into a wall outlet with a double-male cord. It can energize utility lines and injure or kill line workers, damage equipment, and start fires. Always use a transfer switch or interlock installed by a licensed electrician, following local code and permits.

Step 5: Size your generator

Add up the loads you want to run at the same time.

  1. Heating system: from the nameplate, including startup surge.
  2. Refrigerator and freezer.
  3. Sump pump, if you have one. Winter thaws can make it essential.
  4. Well pump, if you have one. Often 240V with a large surge.
  5. Lights, internet, phone charging.
  6. Anything else essential, such as medical devices.

Then add headroom. Generators should not run at their maximum rating for long periods. Many people target a load that is comfortably below the rated running watts.

For a typical home with a gas furnace, a refrigerator, a sump pump, and lights, a mid-size generator in the several-thousand-watt range with a transfer switch often covers essentials. Homes with well pumps or heat pumps need more.

Step 6: Plan your fuel

Winter outages can last days. Your heating system may run for hours at a time in cold weather, so plan fuel carefully.

Read our guide on how long a generator can run for runtime and refueling guidance.

Dual-fuel inverter generator (mid-size)

$$$

Best for Running a gas furnace, fridge, and essentials cleanly

Inverter output is gentle on furnace control boards, and dual fuel lets you use propane, which stores indefinitely. Size it for your furnace plus essentials, and connect it through a transfer switch or interlock.

Generator inlet box and power cord

$$

Best for Completing a safe transfer switch or interlock setup

The outdoor inlet and a properly rated cord are the pieces that connect your generator to your transfer switch or interlock. Match the plug type and amperage to your generator and inlet, and have an electrician install the inlet.

Carbon monoxide: the number one danger

Portable generators produce carbon monoxide, a colorless, odorless gas that can kill quickly. The U.S. Consumer Product Safety Commission estimates that an average of about 80 people die each year from carbon monoxide poisoning associated with portable generators.

Winter outages are especially dangerous because people are tempted to run generators in garages, basements, or near windows to keep them out of the snow.

Safety

If a CO alarm sounds or anyone feels dizzy, nauseated, or weak, get everyone out into fresh air immediately and call 911. Do not go back inside until emergency responders say it is safe.

Battery-powered carbon monoxide alarm

$

Best for Every home that uses a generator

Battery-operated or battery-backup CO alarms keep working when the power is out. Install them on every level and outside sleeping areas.

Keeping the heat in

A generator can run your heating system, but reducing heat loss makes everything easier:

Battery power stations as heating backup

Large LiFePO4 power stations can run boiler circulators, pellet stoves, and even some furnace blowers for limited periods, silently and indoors, with no fumes. They cannot run a heat pump for long or sustain electric resistance heat. They pair well with solar charging and with a generator for recharging.

A winter outage checklist

  1. Have your transfer switch or interlock installed before winter.
  2. Test your generator monthly, and do a full test with your furnace connected.
  3. Store fuel with stabilizer, or keep propane on hand.
  4. Check CO alarms and replace batteries.
  5. Get a generator cover rated for use while running.
  6. Know how to switch your panel over to generator power.
  7. Keep extension cords rated for outdoor use and the load you plan to run.
  8. Keep flashlights, warm blankets, and a plan for the most vulnerable people in your household.

Before the next storm: a one-weekend prep plan

Saturday morning: find the nameplates on your furnace or boiler, well pump, and sump pump. Photograph them and write the amperage on a card you keep with the generator.

Saturday afternoon: call a licensed electrician about an interlock kit or transfer switch if you do not already have one. Ask whether your furnace circuit is on its own breaker and whether a dedicated furnace transfer switch makes sense for your house.

Sunday: start the generator, run it under load for a while, and check the oil. Buy fuel stabilizer, confirm your fuel containers are in good condition, and put fresh batteries in every CO alarm. That single weekend handles most of what goes wrong in winter outages.

Frequently asked questions

Will a gas furnace work during a power outage?

No. Gas furnaces need electricity for the blower, draft inducer, igniter, control board, and gas valve. A properly connected generator can run it.

What size generator do I need to run a furnace?

Check the blower motor amperage on the nameplate. Most gas furnaces can be run by a mid-size generator, but size for the furnace plus the other essentials you want to run at the same time, with headroom.

Can I plug my furnace into a generator?

Furnaces are usually hardwired. You need a transfer switch, interlock, or dedicated furnace transfer switch installed by a licensed electrician. Never backfeed through a wall outlet.

Can a portable generator run a heat pump?

Sometimes, but it requires a large 240V generator, disabling electric backup heat, and often a soft-start kit. Consult an HVAC technician.

Do I need an inverter generator for my furnace?

Many technicians recommend clean power for electronic control boards. An inverter generator, or a conventional generator with low rated harmonic distortion, is the safer choice.

Where should I place a generator during a winter storm?

Outdoors, at least 20 feet from the house per CPSC guidance, with the exhaust pointed away from doors, windows, and vents. Never in a garage. Use a cover rated for use while running.